User's Manual

6-6
1010NFM-3JSection 6
To move the highlight to [Install Flow Tube] press . Press to access the Install Flow Tube
menu.
To access the Flow Tube option list press . Note that this list shows the currently available flow
tube sizes. The number is the size (e.g., 1). The letter represents the material (e.g., S = Steel, P =
PVC, T = Teflon, K = Kynar). In this example, we will install a size 1S Flow Tube. This 1011FTP-1S
(Stainless Steel) unit uses a 5/8” Swagelok Tube Fitting.
To select size 1S press . This moves the highlight to [Install Completed?].
ENT
Siemens 2 Channel [1] FLOW1
Select FlowTube 1S
Install Completed? No
Empty FlowTube Set Chan Not Setup
Zero Flow Adjust Chan Not Setup
Pick Flow Tube size and Type
Install FlowTube
Siemens 2 Channel [1] FLOW1
Select FlowTube >1S
Install Completed? 1P
Empty FlowTube Set 1K
Zero Flow Adjust 1T
2S
2P
2K
2T
Pick Flow Tube size and Type
Install FlowTube
Note that the next menu down is Liquid Data. This menu allows you to enter Viscosity (in centistokes)
and the Density (specific gravity) data for the liquid to be measured. Data entry in this menu is
optional. The default values are those of Water at 68
°F (20°C). If you choose to edit these param-
eters, you should be aware that the viscosity of the liquid is an important factor. It governs the degree
of Reynolds Number compensation that the flow computer applies to the final rate output. Therefore,
flow data errors could result if you enter inaccurate data. Note that the Siemens Technical Service
Group may be able to provide the viscosity data for the liquid to be measured.