User manual

Configuration
58
Siemens Building Technologies
Fire Safety & Security Products 01.2009
8.10 Storage screen
Fig. 65 Storage Menu
Storage Information screen
Highlight Storage Information in the Storage menu and press the
button.
Î The Storage Information setup screen appears and displays information about
the DVR’s storage devices.
Fig. 66 Storage Information screen
The capacity of the storage device is displayed in the box beside Capacity.
The box beside Disk Bad displays the percentage of bad sectors. "Not formatted"
indicates the device is not formatted.
The box beside Temperature displays the temperature of the storage device.
The box beside S.M.A.R.T. displays “Good”, “Bad” or “N/A”, depending on storage
conditions:
Good The storage condition is normal.
Bad Data cannot be written on or read from the storage device.
N/A Storage conditions are normal, however, the S.M.A.R.T. monitoring is not working or
supported.
NOTE
When the storage condition is “Bad”, the Event Status – Storage screen displays and you can check
the storage condition for details. Once the “Bad” message displays, replacing the hard disk drive is
recommended, usually within 24 hours.
NOTE
Temperature and S.M.A.R.T. information will be available only for internal hard disk drives supporting
the SMART (Self-Monitoring Analysis and Reporting Technology) monitoring program.
Not Formatted” displays in the upper part of the Format… box if the hard disk
drive has not been formatted. Highlight the Format… box and press the
button
to format the device for recording.
Î Selecting Close and pressing the button exits the screen.