User manual
Configuration
56
Siemens Building Technologies
Fire Safety & Security Products 01.2009
6. Configure the port’s setting based on the PTZ camera manufacturer’s
instructions.
Î You can save your Camera changes by highlighting OK and pressing the
button.
Î Selecting Cancel exits the screen without saving the changes.
8.9.2 Alarm-Out screen
Highlight Alarm-Out in the Devices menu and press the button.
Î The Alarm-Out screen allows you to change the settings and establish a
schedule for each alarm output from the DVR.
Fig. 63 Alarm-Out Settings screen
Highlighting the box beside Dwell Time and pressing the
button allow you to set
the dwell time of the alarm output. Dwell times range from 5 seconds to 15 minutes.
You can add and edit alarm output schedules on this screen. Highlight the "+" and
press the
button to add a schedule. Highlighting the boxes under the column
heading and pressing the
button allow you to edit the information in those boxes.
The Day box allows you to select the days that the alarm schedule will be active.
The choices are: Sun, Mon, Tue, Wed, Thu, Fri, Sat, M~F, Hol and All.
The Range box allows you to set the time that the alarm schedule will be active in
15-minute increments from 00:00 to 24:00.
The Mode box allows you to set how the alarm reacts during the scheduled time.
When set to On, the Alarm-Out is active during the scheduled time. When set to
Event, the Alarm-Out is only active when there is an Event during the scheduled
time.
The Alarm-Out box allows you to select between Alarm Output and Beep (DVR’s
internal buzzer).
The
box allows you to delete an alarm output schedule. You will be asked to
confirm whether or not you really wish to delete the schedule.
Î You can save your Alarm-Out changes by highlighting Save and pressing the
button.
Î Selecting Cancel exits the screen without saving the changes.