User manual

Configuration
49
Siemens Building Technologies
Fire Safety & Security Products 01.2009
Fig. 50 Check Recording screen
Highlighting the box under the Interval heading beside each alarm-in and
pressing the
button allows you to change the interval that you want the
DVR to run self-diagnostics on Alarm Inputs. You can select from 1 hr. to 30
days or “Never".
3. Highlight the Storage tab and the Storage screen displays.
Fig. 51 Storage screen
Storage
1. Highlight the box beside Disk Bad Notify, and press the
button.
Î Select percentage level of bad disk sectors at which you want the DVR to
trigger an alert. Percentage levels range from 10% to 90%.
2. Highlight the box beside Disk Almost Full Notify, and press the
button.
Î Select the percentage level of disk usage at which you want the DVR to
trigger an alert. Percentage levels range from 80% to 99%.
3. Highlight the first box beside Disk S.M.A.R.T., and press the
button.
4. Use the Up and Down arrow buttons to scroll through the numbers. Refer to
the hard disk drive manufacturer’s documentation for the correct temperature
setting.
Î If the temperature of hard disk drive exceeds the defined threshold, the
system triggers an alert.
5. Highlight the second box beside Disk S.M.A.R.T., and press the
button.
6. Select either ºC (Celsius) or ºF (Fahrenheit), and press the
button.
7. Highlight the Actions tab and the System Event Actions screen displays.