User manual
Configuration
48
Siemens Building Technologies
Fire Safety & Security Products 01.2009
5. Highlight OK and press the button to accept your changes.
NOTE
For the Notify action, the notify item you select should be enabled in the Notification setup screen
and the DVR should be registered in the RAS (Remote Administration System).
6. Highlight the desired box under the PTZ heading, and press the
button.
Î A list of PTZ presets appear.
7. Select the preset positions for each PTZ camera, where you want PTZ
cameras to move to when the DVR detects text input.
Î You can save your Text-In changes by highlighting Save and pressing the
button.
Î Selecting Cancel exits the screen without saving the changes.
8.7.5 System Event screen
Highlight System Event in the Event menu and press the button.
Î The System Event setup screen appears.
Fig. 49 Health Check screen
Health Check
The DVR can be configured to run self-diagnostics and report the results.
Highlighting the box beside System and pressing the
button allows you to select
the interval that you want the DVR to run self-diagnostics on the system. You can
select from 1 hr. to 30 days or “Never".
1. Highlight the Setup... box beside Check Recording and press the
button.
Î The Check Recording screen appears.
2. Highlighting Schedule On and pressing the
button toggles On and Off.
Î When set to On, you can select the day, time range and interval that you want
the DVR to run self-diagnostics on the recorder. The Interval can be selected
from 1 min. to 7 days or “Never". The
box allows you to delete a check
recording schedule.