User manual
Configuration 
65 
Siemens Building Technologies   
Fire Safety & Security Products    12.2008
  NOTE 
The maximum recording speed of each camera group will be limited to 100 ips when set to 
Standard 
resolution, 50 ips when set to High resolution and 25 ips when set to Very High resolution
 for all 
cameras. 
When set to High resolution for all cameras within the same camera group, the DVR records video 
from each camera as fast as possible according to the preset recording speed within the total ips of 
each camera group. When the total ips are higher than the maximum recording speed of the camera 
group, the ips of each camera might decrease so as not to exceed the maximum recording speed. For 
example, if set to High resolution for all cameras within the same camera group of the 8-channel 
model DVR, 15 ips for Time recording and 25 ips for Event recording, the event-driven video from one 
camera will be recorded at 20 ips and the video from the three other cameras will be recorded at 10 
ips each when events are detected by one camera. 
The maximum recording speed per camera will be 6 ips per camera when set to On and Very High 
resolution for four cameras in the same camera group of the 16-channel DVR. See the table below. 
No. of cameras set to On and Very High resolution 
0  1  2  3  4  5  6  7  8 
─  25 ips  12 ips  8 ips  6 ips  5 ips  4 ips  3 ips  3 ips 
The maximum recording speed per camera will be 12 ips per camera when set to On and Very High 
resolution for two cameras in the same camera group of the 8-channel DVR. See the table below. 
No. of cameras set to On and Very High resolution 
0  1  2  3  4 
─ 25 ips 12 ips  8 ips  6 ips 
1.  Highlight the PTZ tab, and the PTZ setup screen displays. 
Fig. 75  Camera PTZ setup screen 
NOTE 
You will only be able to set up PTZ devices if the PTZ port is set to RS232 or RS485. 
2.  Highlight the box in the Product column for the PTZ camera you wish to 
configure and press the 
 button. 
Î A list of PTZ devices appears. 
3.  Select your camera from the list and press the 
 button. 
Î You will need to connect the camera to the RS232 or RS485 connector on the 
back of the DVR following the camera manufacturer’s instructions. 