User manual
Configuration 
42 
Siemens Building Technologies   
Fire Safety & Security Products    12.2008
Fig. 40  Port Numbers setup screen 
7.  Change the numbers by highlighting them and using the Up and Down arrow 
buttons to increase or decrease the number. 
The factory default port settings are: 
Remote Admin:  8200 
Remote Callback:  8201 
Remote Watch:  8016 
Remote Search:  10019 
Remote Audio:  8116 
NOTE 
The system restarts automatically after changing the port settings. 
  NOTE 
Do NOT use the same port number for two different programs, otherwise, the DVR cannot be 
connected with the PC running RAS or Web Client. 
  NOTE 
When changing the port settings, you must change the port settings on the PC running RAS or Web 
Client as well. Refer to the RAS manual for details. 
Î Selecting "DHCP" from the Type and highlighting the Save button reads the 
current IP address of the DVR configured by DHCP (Dynamic Host 
Configuration Protocol) network. 
Fig. 41  LAN (DHCP) setup screen 
Î Selecting "ADSL (with PPPoE)" allows you to set up the ADSL network. 