User manual
Configuration 
31 
Siemens Building Technologies   
Fire Safety & Security Products    12.2008
3.  Highlight the slide bar beside Limit Time-Lapse Recording, and use the Left 
and Right arrow buttons to adjust the length of the maximum storage time for 
time-lapse recording from 1 to 99 days. 
Î The Limit Time-Lapse Recording feature will function when the storage device 
has enough space to record video data longer than the preset period. When 
this feature is On, the DVR records over the oldest “time-lapse” video once all 
available storage has been used in the Recycle mode, so more event video 
can be saved. Selecting Never will disable the Limit Time-Lapse Recording 
function. 
  NOTE 
When the storage device does not have enough space to record video data longer than the preset 
Limit Time-Lapse Recording period, the DVR records over the oldest video data (time-lapse or event 
video) as it would in the Recycle mode even if this feature is turned On. 
  NOTE 
The maximum storage time is only an estimate because the amount of space required to store video 
varies depending on many factors such as motion and image complexity. 
CAUTION 
When more than one disk is installed in the unit, the DVR records video on the disks 
sequentially based on time. And these sequentially recorded videos have the 
advantage that you can search recorded video easily even though a disk is removed 
from the unit. However, video recorded in the same time range might be saved on 
different disks by channel and by the type of recording mode. Once the Limit Time-
Lapse Recording is set to On, the DVR will maintain this recording limitation even 
after disabling the function. If you want the DVR to record video on the disks 
sequentially based on time again, you must format all disks that are currently used 
for recording. 
4.  Highlight the Panic Recording – Duration box and set the duration of panic 
recording. 
Î Panic recording will stop automatically after the preset duration as long as the 
Panic button is not pressed to stop the panic recording. You can set the dwell 
from 5 minutes to 1 hour. Select "No Limit" if you want to stop panic recording 
manually. 
Highlighting the Panic Recording – ips box and pressing the 
 button 
allows you to set the images per second for Panic recording. You can select 
from 1.00 to 25.00 (30.00 for NTSC) images per second. 
Highlighting the Panic Recording – Quality box and pressing the 
 button 
allows you to set the recorded image quality for Panic recording. You can 
select from: Very High, High, Standard and Low. 
Î You can save your Record settings by highlighting Save and pressing the   
button. 