Computer Drive Installation Instructions
7 Drive Machine Data (SIMODRIVE Drive MD) 12.93
7.1.2 MSD MD (data description - SW 3)
Shift factor signal 2
216
Default value Lower input limit Upper input limit Units
0 0 15 –
Active
at once
Input of shift factor for signal 2 (see also MD 206). The top 8 bits from a 16-bit wide memory
location are output. This machine data specifies how often the value must be shifted to the left
beforehand.
Trigger signal value 1
217
Default value Lower input limit Upper input limit Units
0000 0000 FFFF Hex
Active
at once
Input of low amplitude for the trigger signal value (see also MD 206).
A 1 ms long trigger signal can be output on commencement of the analog output.
Trigger signal value 2
218
Default value Lower input limit Upper input limit Units
7FFF 0000 FFFF Hex
Active
at once
Input of high amplitude for the trigger signal value (see also MD 206).
A 1 ms long trigger signal can be output on commencement of the analog output.
Motor moment of inertia motor 2
219
Default value Lower input limit Upper input limit Units
Depends on motor 0.002 32.000 kgm
2
Active on
Power On
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated power motor 2
220
Default value Lower input limit Upper input limit Units
Depends on motor 0 150.0 kW
Active on
Power On
Input of motor rated current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated current motor 2
221
Default value Lower input limit Upper input limit Units
Depends on motor 0 200.0 A
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
7–30 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50