Router User Manual
7 Interfacing to the Machine 09.91
7.3.2 Definition of R parameters as cycle machine data, cycle setting data
7.3.2 Definition of R parameters as cycle machine data, cycle setting
data
To protect parameters (R110 to R199) used for the measuring cycles against inadvertent
modification, the parameters can be defined as:
• Cycle machine data (CMD) or
• Cycle setting data (CSD)
The definition is made via general NC machine data 14 to 17.
Definition of area limits with general NC MC 14 to 17.
R parameter
110 to 199 per channel
Where overlaps occur, SDs are dominant.
Any allocation possible.
MD 14 = Cycle MD from
R parameter
number.....
MD 16 = Cycle SD from
R parameter
number.....
MD 17 = Cycle SD to
R parameter
number.....
MD 15 = Cycle MD to
R parameter
number.....
Cycle MD
Cycle MD
Cycle SD
7-6 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)