4 Monitoring Functions 11.90
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
3028
”Too many fields/variables”
Remarks: Alarm only on commissioning
Alarm No.
Alarm Text:
3029
”Graphics option not available”
Reason:
Remedy:
Explanation:
Graphic elements have been projected into the selected display, but
the ”Graphics” option is not fitted in the control
Retrofit ”Graphics” option
Only project display without graphic elements
Only with additional programming developed in WS 800
Alarm-No.
Alarm Text:
3030
”Cursor memory not available”
Reason:
Remedy:
Explanation:
The cursor memory programmed for the display selected is not correct
(number not allowed or too large).
Use the workstation to redefine the cursor memory
The function of the cursor memory is to position the cursor where it
was previously when the display is called again.
Only with additional programming via WS 800
Alarm-No.
Alarm Text:
3032
”Too many fields / variables”
Remarks: Alarm only on commissioning
Alarm-No.
Alarm Text:
3033
”Display text not available”
Reason:
Remedy:
Explanation:
An error has occurred while linking with the workstation.
Check link list, and relink with the workstation (to clear link error).
Only with additional programming via WS 800
Alarm only on commissioning
Alarm-No.
Alarm Text:
3034
”Text not available”
Explanation: Only with additional programming via WS 800
Alarm only on commissioning
Alarm-No.
Alarm Text:
3040
”Fields / var. not displayable”
Explanation: Only with additional programming via WS 800
Alarm only on commissioning
Alarm-No.
Alarm Text:
3041
”Too many fields / variables”
Remarks: Alarm only on commissioning
4-30
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02