Router User Manual

09.91 4 Monitoring Functions
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
2046
”Block greater than 120 characters”
Reason:
Effect:
Remedy:
There is an incorrect ”LF” in the memory, so that a block containing
more than 120 characters exists.
Inhibiting of NC START
Either insert ”LF”, or delete the complete block
Alarm No.
Alarm Text:
2047
”Option not available”
Reason:
Effect:
Remedy:
A function was programmed that is not included in the function set of
the control.
Inhibiting of NC START
Correct program
Alarm No.
Alarm Text:
2048
”Circle endpoint error”
Reason:
Effect:
Remedy:
The programmed circle endpoint does not lie on the circle.
The tolerance band set in machine data is exceeded.
Inhibiting of NC START
Correct program
Alarm No.
Alarm Text:
2056
”Travel through transf. center”
Explanation:
Remedy:
On the programmed contour, the radius axis (linear axis) wants to
traverse into the zero of the fictitious coordinate system.
Change cutter radius.
Program a different contour.
Alarm No.
Alarm Text:
2057
”Opt. thread/rev. not avail.”
Reason:
Remedy:
Explanation:
A thread has been programmed in the program with G33, G34, G35
although this function is not available in the control
Feed per rev. G95 has been programmed.
Correct program.
Alarm with SINUMERIK 810M only.
Alarm No.
Alarm Text:
2058
”3D option not avail.”
Reason:
Remedy:
Explanation:
In the program, 3 axes were programmed simultaneously
Correct program
Alarm with SINUMERIK 810M only
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02 4-17
SINUMERIK 810T, GA3 (BN)