11.90 3 Operating Sequences
3.1.15 Data input/data output
Start the output of the R parameters by operating the
”START” softkey.
In the same way, you can select and start the output of data for the following:
”TOOL OFFSET”
”ZERO OFFSET”
”MACHINE DATA”
”PLC MACHINE DATA”
which have not been detailed here.
Using this softkey, you can stop data output at any time...
and continue it again with ”START”.
With the ”ETX-START” softkey you can output the end-
of-transmission character stored in the setting data.
The output is always made irrespective of whether RTS
line or Xon/Xoff protocol have been set.
or or
1
F
2
D
0
S
START
STOP
ETX
START
Using the keyboard, enter the
channel no.:
into the input field marked in
inverse video:
1” for output of local
R parameters, channel 1
2” for output of local
R parameters, channel 2
0” for output of the
global R parameters
Note:
A selection of the data, i.e. the output of a section as with ”PART PROGRAM” - is not possible!
The input of a channel no. is only required by the control for ”R PARAMETERS”.
Data output with or without leader or trailer can be set via setting data (SD 5016, bit 1).