Assigning the instance
In the calling user program, the function block
“FB_BGD_TEMPLATE_FlyingSaw()” must be assigned an instance. The
following table includes examples in ST and FBD.
Table 7-6 Generating an instance of the “FB_BGD_TEMPLATE_FlyingSaw()”
Instance
ST
FUP
7.6.2 Integrating the template block in the processing sequence
The core “flying saw” function is integrated in the processing sequence
using a simple function block call and transferring the required parameters.
This call strategy corresponds to that of PLC-Open standard function