Saw User Manual

Section C: Integrating the core “flying saw” functions
Program environment and interfaces
Flying Saw with SIMOTION A4027118-A0414
V 1.4 Release 06/06/08 71/107
Copyright © Siemens AG 2008 All rights reserved
Manual_SIMOTION Flying Saw_V1.4.doc
Parameter Data type Initial
value
Description
Control information
Restart BOOL false
If the bit is set (e.g. in
the StartUp task), then
the template executes
a re-initialization and
resets the bit.
This bit must
be set
for each new start!
MaterialIn BOOL false
If the bit is set, the
material web is in the
flying saw area.
MaterialInMotion BOOL false
If the bit is set, the
material web in the
flying saw area.is
moving.
Fig. 6-3 Matrix of the relevant technology objects (TOs)
Axis_FlyingSawAxis_Material
Pos_Axis
Following_Axis
External_Encoder
Following_Objekt
Printmark
X--
-- X
(X) --
-- X
X--
(X) In realen Anwendungen kann auch auf einen
externen Geber zugegriffen werden