Saw User Manual
Section B: The application example as demonstration
system
I t lli
th
hd
d
ft
Flying Saw with SIMOTION A4027118-A0414
V 1.4 Release 06/06/08 30/107
Copyright © Siemens AG 2008 All rights reserved
Manual_SIMOTION Flying Saw_V1.4.doc
4.4.3 Re-configuring the double-axis motor module from 3A/3A to 5A/5A
This application example is configured as standard using a 3A/3A motor
module. However, there are demonstration cases in the field, which are still
equipped with a 5A/5A motor module. The hardware should be carefully
checked before the project is downloaded! If a 3A/3A motor module is not
used in the demonstration case, then the project can be re-configured by
following the subsequent instructions:
• Go offline
• In the project tree, open the “Drive Navigator”
• A selection window opens when the “Device configuration” button is
pressed
• Open the Configurator by pressing the “Execute drive configuration"
button
• Scroll in the selection menu of the power unit by pressing the
“Continue” button
• Select the power unit being used from the list – refer to the serial
number on the front of the double motor module, e.g. 6SL3120-2TE15-
0AA0 (5A/5A)
• Press “Continue” and acknowledge the alarm messages
• Press the “Continue” button – without making any additional changes –
until the “Complete” button appears; also press this
• Close the Device Configurator
• In the Expert list of the red and blue drives (select the particular drive ->
righthand mouse key -> Expert -> Expert list), reduce parameter p210
from 600V to 345V
• Compile and save the project, go online and load the project into the
target system