Section B: The application example as demonstration
system
I t lli
th
hd
d
ft
Flying Saw with SIMOTION A4027118-A0414
V 1.4 Release 06/06/08 27/107
Copyright © Siemens AG 2008 All rights reserved
Manual_SIMOTION Flying Saw_V1.4.doc
Table 4-2 Hardware configuration and mounting
No. Action Comment
1
Connect the MPI/DP interface of your PG/PC
to the righthand MPI/DP interface (contact
X136) of the SIMOTION D435 using a
PROFIBUS cable and switch the terminating
resistors in the two terminating connectors of
the cable to “On”.
Do not
use the standard MPI cable,
supplied with the PG/PC to connect the
PG/PC to the SIMOTION D435!
The connection should be operated with a
12Mbit/s baud rate. Under all
circumstances, a PROFIBUS cable must
be used between the PG/PC and
SIMOTION D435 with the terminating
resistors switched-in. If this is not done,
communication problems can occur
between the PG/PC and the SIMOTION
D435.
2
Connect the SIMOTION D training case to
the power supply.
3 Power-up all of the equipment/devices.