Saw User Manual

Section E: Appendix
Error messages
Flying Saw with SIMOTION A4027118-A0414
V 1.4 Release 06/06/08 105/107
Copyright © Siemens AG 2008 All rights reserved
Manual_SIMOTION Flying Saw_V1.4.doc
ErrorID
error code
Explanation
C091 Manual to Disable
Error when stopping the FlyingSawAxis ( move mit v=0)
Details in FS_Var structure under RetDINT_stop_FSA
C092 Manual to Disable
Error when stopping the FlyingSawAxis ( move mit v=0)
Details in FS_Var structure under FR_stop_FSA
C0A1 Manual to Starting position
Error when positioning the FlyingSawAxis ( _pos )
Details in FS_Var structure under RetDINT_pos_FSA
C0A2 Manual to Starting position
Error when positioning the FlyingSawAxis ( _pos )
Details in FS_Var structure under FR_pos_FSA
C0F1 Incorrect mode selection from “error” mode
C0F2 Incorrect mode selection from “disable” mode
C0F3 Incorrect mode selection from “starting position” mode
C0F4 Incorrect mode selection from “automatic” mode
C0F5 Incorrect mode selection from “manual” mode
C101
Parameterizing error at the flying saw axis
Axis is not parameterized as synchronous axis.
C201
Parameterizing error at the material axis/external encoder
The material master (leading) value is neither a positioning axis
nor an external encoder