Saw User Manual
Section E: Appendix
Error messages
Flying Saw with SIMOTION A4027118-A0414
V 1.4 Release 06/06/08 101/107
Copyright © Siemens AG 2008 All rights reserved
Manual_SIMOTION Flying Saw_V1.4.doc
12 Error messages
12.1 Signaling error events at the “FlyingSaw FB” of the core “flying
saw” functions
If an error occurs when calling the “FB_BGD_TEMPLATE_FlyingSaw()” of
the core “flying saw” functions, then this is displayed using an error code at
output
ErrorID of the FB.
If the error is caused by a TO-specific command called from the Flying Saw
FB, then its
RetDINT or FR is documented in the data area FS_Var for
evaluation by the user.
12.2 Possible error messages at the error code output ErrorID of the
„FB_BGD_TEMPLATE_FlyingSaw()“
A reference is made to the internal block error source of the “FlyingSaw FB”
in the
Explanation column.
Table 12-1 Error codes of the flying saw template
ErrorID
error code
Explanation
C001 There is an error at a flying saw axis
C005
Position of the flying saw axis greater than that specified under
UsersInterface.g_r_EndPos.
C011 Disable to Disable
Error when stopping the FlyingSawAxis ( _stop )
Details in FS_Var structure under RetDINT_stop_FSA
C012 Disable to disable
Error when stopping the FlyingSawAxis ( _stop )
Details in FS_Var structure under FR_stop_FSA