Technical data

Mounting
3-3
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/02
3.1.2 Panel PC 870
A mounting cut-out is required as shown in the figure and explanatory table
below:
W
+1
H
+1
Rz 120
min. 1.5 to max. 6
D
+1
186
0.5
135
0.5
5
0.5
24
0.5
24
0.5
1
)
*
)
Operating units W H D
2
) D
3
)
(a) with key-based front panels:
10. TFT / 12.1 TFT 450 290 100 69
15.1 TFT 450 321 130 91
(b) with touchscreen front panels:
12.1 TFT 368 290 85
15.1 TFT 450 290 130 91
1
) cutouts only for 15 TFT (keyboard version)
2
) mounting depth standard mount form factor,
operating and computing unit
3
) mounting depth remote mount form factor,
only operating unit
Fig. 3-2 Mounting cut-out for standard mounting of Panel PC 870 (width x height x depth in mm)
When installing in an enclosed housing, ensure that there is sufficient vo-
lume for air circulation and, if necessary, for swinging out the computing
unit (see also Figure 2-10 and 4-1).
The maximum air intake temperature must not exceed 45°C.