Technical data

Electromagnetic Compatibility 11/01
4–2 SIMATIC Panel PC 670/870 Commissioning Instructions
A5E00135748-01
Sinusoidal wave interference
RF radiation complying with EN 61000-4-3
Electromagnetic RF field, amplitude-modulated
from 80–1000 MHz
10 V/m
80 % AM (1 kHz)
Electromagnetic RF field, pulse-modulated
900 ± 5 MHz
10 V/m
50 % ED
200 Hz Pulse Repetition Frequency
RF interference on signal lines, data lines, etc. complying with EN 61000-4-6,
radio frequency, asymmetric, amplitude-modulated
from 0.15 –80 MHz
10 V RMS value
80 % AM (1 kHz)
Interference emission
Radiated interference of electromagnetic fields complying with
EN 55011: Limit Value Class A, Group 1.
From 30–230 MHz < 30 dB (µV/m)Q
From 230–1000 MHz < 37 dB (µV/m)Q
Measured from a 30 m distance
Radiated interference from AC line power supply complying with
EN 55011: Limit Value Class A, Group 1 (only 230V device)
From 0,15–0,5 MHz < 79 dB (µV)Q
< 66 dB (µV)A
From 0.5–5 MHz < 73 dB (µV)Q
< 60 dB (µV)A
From 5–30 MHz < 73 dB (µV)Q
< 60 dB (µV)A