Technical data
Installing and Connecting the Panel PC 670/870 11/01
1–4 SIMATIC Panel PC 670/870 Commissioning Instructions
A5E00135748-01
Installation cut-out
When selecting the installation cut-out, ensure that the switching cabinet/panel
contains reinforcement bars to stabilize the plate. If necessary, install such
reinforcement bars.
An installation cut-out is required corresponding to the following diagram:
Unit depth T
PC 670
114
142
202
227
–
137
–
229
PC 870
2 to 6
H
+1
B
+1
T
+1
Unit depth T
2
All figures in mm.
Installation cut-out
Panel PC 670/870, 12", Keys
Panel PC 670/870, 15", Keys
B H
450
450
295 ± 0,5
326 ± 0,5
368
450
290
290
Panel PC 670/870, 12", Touch
Panel PC 670/870, 15", Touch
Figure 1–3 Installation Cut-out for Standard Installation
Specifications without the CD-ROM option.
Note
Ensure sufficient air volume for heat transportation within the switching
cabinet/panel. There must be at least 100 mm free space around the
Panel PC 670/870. 10 mm are permissible on the rear side.
Also ensure sufficient free space to pull out the Panel PC 670/870 from the
installation cut-out.