Technical data

Technical data
7.4 Mechanical and Climatic Ambient Conditions for Operation of the TS Adapter IE Basic
TS Adapter IE Basic
Manual, 08/2014, A5E02615140-03
71
Testing of mechanical environmental conditions
The table below provides information on the type and scope of testing of mechanical ambient
conditions.
Table 7- 5 Testing of mechanical environmental conditions
Test of ...
Test standard
Comments
Vibration Vibration test to
IEC 60068-2-6 (sine
wave)
Vibration type: Frequency sweeps at a rate of
change of 1 octave per minute.
5 Hz ≤ f < 9 Hz, constant amplitude 3.5 mm
9 Hz ≤ f < 150 Hz, constant acceleration 9.81 m/s
2
Vibration period: 10 frequency sweeps per axis on
each of the 3 perpendicular axes
Shock Shock impact test to IEC
60068-2-29
Type of shock: Half-sine shock pulse
Shock intensity: 150 m/s
2
peak value, 11 ms period
Direction of shock: 100 pulses on each of the 3
perpendicular axes
Climatic ambient conditions
The TS Adapter IE Basic can be operated under the following climatic ambient conditions:
Table 7- 6 Climatic ambient conditions
Ambient conditions
Permitted range
Comments
Temperature 0 to +60° C
0 to +40° C
Horizontal installation
Vertical installation
Temperature change
Max. 3° C per min.
Relative humidity Max. 95% at +25° C No condensation,
corresponding to RH
loading level 2 to
IEC 61131-2.
Barometric pressure 1080 to 795 hPa (corresponding to
an altitude of -1000 to 2000 m)
-
Pollutant concentration SO
2
: <0.5 ppm;
RH <60%, no condensation
H
2
S: <0.1 ppm;
RH <60%, no condensation
Test: 10 ppm; 4 days
Test: 1 ppm; 4 days