Technical data
Technical data
7.2 Electromagnetic Compatibility
TS Adapter IE Basic
68 Manual, 08/2014, A5E02615140-03
Sinusoidal interference
The table below shows the EMC characteristics of the TS Adapter IE Basic with regard to
sinusoidal disturbance variables.
Table 7- 2 Sinusoidal interference
Sinusoidal interference
Test values
Equivalent to
severity
HF irradiation (electromagnetic fields) according to
IEC 61000-4-3
10 V/m with 80% amplitude modulation of 1 kHz
in the range from 80 MHz to 1000 MHz and
1.4 GHz to 2 GHz.
1 V/m with 80% amplitude modulation of 1 kHz in
the range from 2 GHz to 2.7 GHz
3
RF current coupling on cables and cable shields to
IEC 61000-4-6
Test voltage 10 V, with 80% amplitude modulation
of 1 kHz in the 10 MHz to 80 MHz range
3
Radio interference emission
Interference emission of electromagnetic fields in accordance with EN 61000-6-4.
Additional measures
If you wish to operate the TS Adapter IE Basic in an office area, you must implement
additional measures to meet the requirements of EN 61000-6-3.
Take suitable additional measures if you need to increase the interference immunity of the
system due to high external interference levels.