Technical data

TS Adapter IE Basic
Manual, 08/2014, A5E02615140-03
55
Error diagnostics
6
6.1
Error Diagnostics Based on LEDs
With the help of the LED displays, simple disruptions can be diagnosed and repaired
independently.
Table 6- 1 LED display for operating state of the TS Adapter IE Basic
LED
Cause
Measures/remedy
RUN
(green/yellow)
ERROR
(red)
MAINT
(yellow)
Illuminated
green
The TS Adapter IE Basic is
ready for operation.
Off
Off
Off
No power supply
Establish the power supply.
Lit
No TS module inserted
Insert a TS module.
TS module defective
Replace the TS module.
Error during the modem
initialization
Open the Web interface of the
TS Adapter IE Basic and have
the errors displayed in the
"Information > Status" tab.
Correct the modem
initialization.
Details about errors can be
found in the LOG file.
Lit
Unknown or new TS module
Make a firmware upgrade.
Lights up yellow
Lit
The firmware is downloaded.
Wait until the
TS Adapter IE Basic is ready
for operation.
Blinks
green/yellow
Flashes Flashes Hardware test and interface
initialization
Flashes yellow 3
times
You have restored the factory
settings in the Web interface or
with the reset button RES.
Check to see if the factory
settings fit to your system
configuration.
Flashes Firmware update in progress. Wait until the
TS Adapter IE Basic is ready
for operation.
Lights up yellow
Flashes
Off
Error during firmware update
Repeat the firmware update.
Flashes
green/yellow for
3 s
Flashes for 3 s Flashes for 3 s Displays the selected
TS Adapter IE Basic
any