Technical data

Commissioning
4.7 Parameter assignment of TS Adapter IE - Overview
TS Adapter IE Basic
Manual, 08/2014, A5E02615140-03
39
4.7
Parameter assignment of TS Adapter IE - Overview
Overview
You can use the Web interface of the TS Adapter IE Basic to:
Parameterize the TS Adapter IE Basic.
Restore the standard setting of the TS Adapter IE Basic.
Export the parameter set of the TS Adapter IE Basic.
Import the parameter set of the TS Adapter IE Basic.
Useful facts about configuration
You can configure the TS Adapter IE Basic parameters by direct connection or over a
remote connection.
Note
If you make changes in one tab of the Web interface and open another tab withou
t saving
your changes, the changes will be discarded without warning.
If you enter inadmissible values in a tab, the input fields in question are colored red as
soon as you click "Save Settings". The incorrect values are not saved in this case.
Correct the incorrect inputs and click "Save Settings" again. As long as you have not yet
saved your input in a tab by clicking "Save Setting", you can cancel them by clicking
"Discard Changes".
The configuration data are written to the nonvolatile memory of the TS Adapter IE Basic.
If you change the current parameters while a remote connection is open, there is a risk
that you may not be able to establish a modem connection again with the changed
parameters. In this case, you can only set the TS Adapter IE Basic through a direct
connection.
That means that you must configure the TS Adapter IE Basic using a PG/PC on-site or
you must take the TS Adapter IE Basic to the location of the local PG/PC to configure its
parameters there.