Specifications
Specifications
9.5 Transportation and Storage Conditions
TS Adapter IE
Manual, 06/2008, A5E00977705-02
87
Additional measures
If you want to operate the TS Adapter IE in an office environment, you must ensure
compliance with limit class B to EN 55022.
Take suitable measures for increasing resistance to high external interference levels as
required.
9.5 Transportation and Storage Conditions
Transportation and storage of modules
The TS Adapter IE exceeds requirements to IEC 61131-2 with respect to transportation and
storage conditions. The following specifications apply to TS Adapter IE units which are
transported and stored in their original packaging.
Climatic conditions compliant with IEC 60721-3-3, class 3K7 for storage and IEC 60721-3-2,
class 2K4 for transportation.
Mechanical conditions compliant with IEC 60721-3-2, class 2M2.
Table 9-3 Transportation and storage conditions for modules
Permitted range
Temperature -40 to +70° C
Barometric pressure 1080 to 660 hPa (corresponding to an altitude of -1000 to
3500 m)
Relative humidity (at +25° C) 5 to 95%, without condensation
Sinusoidal vibration to IEC 60068-2-6 5 - 9 Hz: 3.5 mm
9 - 500 Hz: 9.8 m/s
2
Shock impact to IEC 60068-2-29 250 m/s
2
, 6 ms, 1000 shocks