Technical data
Sending E-mail
TeleService V6.1 Service Software for SIMATIC S7 and C7
11-2 A5E00921336-01
You also need the program blocks from the standard library of STEP 7 described
below.
In addition, the "Use gateway / router" property must be set for the Ethernet
interface in the configuration of the CPU on which FB 49 "AS_MAIL" is executed.
(This is found under: Hardware Configuration > PROFINET IO (PN-IO) > General >
Properties > Parameters). The IP address of the Ethernet interface of the
TS Adapter IE should be specified as the "Address" .
Required Program Blocks
FB 49 "AS_MAIL" requires the following FCs from the standard library of STEP 7 in
the "IEC Function Blocks" folder:
• FC 10 "EQ_STRNG",
• FC 11 "FIND",
• FC 17 "INSERT",
• FC 20 "LEFT",
• FC 21 "LEN" and
• FC 32 "RIGHT".
You need to copy these blocks from the standard library of STEP 7 into your
project and to your CPU.
Note
You can find additional information about this in the help for the
TeleService S7 Library.