Technical data

Introducing TeleService
TeleService V6.1 Service Software for SIMATIC S7 and C7
1-8 A5E00921336-01
Working with a direct connection:
1. Start "Set PG/PC Interface" from the Control Panel and set the "TS Adapter"
interface for a direct connection.
2. Set the parameters for the TS Adapter for a direct connection. To do this,
select the menu command Options > Assign TS Adapter I/II Parameters.
You can also export, import and reset the parameter settings of a
TS Adapter I/II as well as set up access protection for the adapter parameter
assignment and for the remote plant.
3. In the "Set PG/PC Interface" dialog box, set the access point of your SIMATIC
application (for example, "S7ONLINE (STEP 7)" to the "TS Adapter" interface.
4. You can now start the SIMATIC Manager and establish a connection to the
connected automation system via the TS Adapter.
Working with a modem connection:
1. Start "Set PG/PC Interface" from the "Option" menu and set the "TS Adapter"
interface to modem connection.
2. In the "Set PG/PC Interface" dialog box, set the access point of your SIMATIC
application (for example, "S7ONLINE (STEP 7)" to the "TS Adapter" interface.
3. Create phone books, folders and plants in TeleService. In plants you save the
data which are required to establish a remote connection.
4. Establish the remote connection to the desired plant using the Connection >
Establish menu command or by double-clicking on a plant.
5. After the remote connection has been established, you can switch to your
SIMATIC application and access the report plant as with a direct connection.
You can also display the properties of the active remote connection.
6. Disconnect the remote connection after you have completed your work.