1.3 Performance features
You can operate the TS Adapter II on MPI networks, PROFIBUS networks, and
homogeneous PPI networks. The TS Adapter II corresponds basically to a PC Adapter USB.
Baud rates and bus profiles
The following table shows the baud rates supported by the TS Adapter II on various network
types.
Table 1-1 Bus profiles and baud rates
PROFIBUS
Baud rate MPI PPI
DP Standard Universal User-
defined
9,600 bps - ✔ ✔ ✔ ✔ ✔
19,200 bps ✔ ✔ ✔ ✔ ✔ ✔
45,450 bps - - ✔ ✔ - ✔
93,750 bps - - ✔ ✔ ✔ ✔
187,500 bps ✔ ✔ ✔ ✔ ✔ ✔
500 kbps - - ✔ ✔ ✔ ✔
1500 kbps ✔ - ✔ ✔ ✔ ✔
3 Mbps ✔ - ✔ ✔ - ✔
6 Mbps ✔ - ✔ ✔ - ✔
12 Mbps ✔ - ✔ ✔ - ✔
Performance features of the TS Adapter II
● Connection to PC via USB
● Automatic bus profile detection
● Up to 16 communication connections, including a maximum of 4 slaves
(DP/T connections)
● Support for routing
● Support for "PG_DIAL", "AS_DIAL", "SMS_SEND" function blocks
● External voltage supply possible
● A DIN rail mounting is also integrated.