Operating Instructions (Compact) SIMATIC Industrial PC SIMATIC Panel PC 877 Operating Instructions (Compact) Edition 07/2006 A5E00877751-01 1
Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. Danger indicates that death or severe personal injury will result if proper precautions are not taken.
Operating Instructions (Compact) 1.1 1 Unpacking and checking the delivery Procedure 1. Please check the packaging material for transport damage upon delivery. 2. If any transport damage is present at the time of delivery, lodge a complaint at the shipping company in charge. Have the shipper confirm the transport damage immediately. 3. Unpack the device. Caution Do not lie the device on its back. This will avoid any damage to an optical drive which may be present.
Operating Instructions (Compact) 1.2 Device identification data 1.2 Device identification data Enter the identification data of the device into the table: SVP number (on the type plate) Order number of the device For the Windows 2000 / XP Professional variants: Microsoft Windows Product Key from the "Certificate of Authenticity" (COA). The COA label is attached to the device Ethernet addresses: BIOS Setup (F2 Key) under Main > Hardware Options > Ethernet Address 1.
Operating Instructions (Compact) 1.5 Installation / panel-mounting 1.5 Installation / panel-mounting 1.5.1 Permitted mounting positions Mounting positions Only vertical installation with a deviation of up to +20° and -20° in the specified directions is permitted for the device.
Operating Instructions (Compact) 1.5 Installation / panel-mounting 1.5.2 Preparing the mounting cut-out The following illustration show the dimensions for the mounting cut-out.
Operating Instructions (Compact) 1.5 Installation / panel-mounting Table 1-1 Dimensions for the mounting cut-out in mm Control unit L1 L2 L3 1) L4 1) L5 L6 2) L7 2) L8 2) L9 2) A1 A2 S1 S2 S3 S4 S53) Tolerance +1 +1 ±0.2 ±0.5 ±0.5 ±0.5 ±0.
Operating Instructions (Compact) 1.5 Installation / panel-mounting 1.5.3 Mounting depth of the device Panel PC with operator units T Key panel with 12" TFT 192 mm Key panel with 15" TFT 211 mm Touch panel with 15" TFT 209 mm Touch panel with 19" TFT 217 mm 7 Note Additional mounting depth with optical drive The installation depth increases by 21 mm when an optical drive is installed in the device.
Operating Instructions (Compact) 1.5 Installation / panel-mounting 1.5.4 Securing the device with clamps You require 6 clamps in order to mount the device with a 12"/15" display. A device with a 19" display must be mounted with 8 clamps. The required number of clamps is included in your Panel PC delivery package. Required tool for fasting the clamps: 2.
Operating Instructions (Compact) 1.5 Installation / panel-mounting IP65 degree of protection The plant builder is responsible for the correct installation of the device. The degree of protection IP65 is only guaranteed for the front of the device if the ring seal is properly applied with the correct size of cutout, the unit has been clamped in place, and the instructions below are observed.
Operating Instructions (Compact) 1.5 Installation / panel-mounting Drilling holes Steps for drilling holes 1 Drill holes (Ø approx. 2.5 mm) from the rear in the 4 recesses of the control unit. 2 Use a Ø 5.5 mm bit for M5 and a Ø 6.5 mm bit for M6 3 Deburr the holes from the front of the control unit Notice Risk of damage Ensure that no metal cuttings enter the device when the holes are drilled. Cover the device with film or when drilling, use removal by suction.
Operating Instructions (Compact) 1.
Operating Instructions (Compact) 1.5 Installation / panel-mounting IP54 degree of protection The IP54 degree of protection is guaranteed for screw mounting together with the ring seal. Caution Observe the panel seal when mounting Ensure you do not damage the panel seal when mounting the device. Notice Control cabinet installation; Material strength at the mounting cut-out Please ensure that the material strength at the mounting cut-out is a maximum of 6 mm.
Operating Instructions (Compact) 1.6 Connecting 1.6 Connecting 1.6.
Operating Instructions (Compact) 1.6 Connecting Connection and operator control components of the right-hand side of the device Pos Designation Description (1) 100 / 240 V AC or 24 V DC Connection for AC or DC power supply (depending on the product variant, the figure shows the AC power plug) The relevant angle is included with the device for interlocking the connector.
Operating Instructions (Compact) 1.6 Connecting Connection components of the control unit USB connection control unit Pos Designation Description (1) USB 1 connection USB 2.0 high current (500 mA) under sealing flap (not available with every product variant). Notice Guarantee for the IP 65 degree of protection When the sealed cover over the USB interface is removed in order to connect a USB component, the IP 65 degree of protection for the device is no longer guaranteed.
Operating Instructions (Compact) 1.6 Connecting 1.6.2 Connecting the 100 V to 240 V AC power supply General connection information Note the following in order to operate the device safely and according to regulation: Note Voltage range The power supply module is designed for operation on 100 to 240 V AC networks. The device adjusts automatically to the voltage. Notice Risk of damage Do not connect or disconnect power and data cables during thunderstorms.
Operating Instructions (Compact) 1.6 Connecting Power Factor Correction The power supply contains an active PFC (Power Factor Correction) circuit to conform to the EMC guidelines. Uninterruptible AC power systems (UPS) must supply a sinusoidal output voltage in the normal and buffered mode when used with SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3.
Operating Instructions (Compact) 1.6 Connecting 1.6.3 Connecting the 24 V DC power supply General connection information Note the following in order to operate the device safely and according to regulation: Notice Power supply The device must only be connected to 24 V DC power supply systems or 24 V DC power supplies which meet the requirements of a safe extra-low voltage (SELV). Use the supplied connector to connect it to the supply voltage.
Operating Instructions (Compact) 1.6 Connecting 1.6.4 Connecting the equipotential bonding circuit A low resistance ground connection ensures that interference signals generated by external power supply cables, signal cables or cables to the I/O modules are safely discharged to ground.
Operating Instructions (Compact) 1.7 Commissioning 1.7 Commissioning 1.7.1 Initial startup Configuring the operating system Note Requirements for initial start-up Before switching on the computer for the first time, check that the equipotential bonding is connected and that all connecting cables are plugged in correctly. Also check that a USB keyboard and a USB mouse are connected to the PC.
Operating Instructions (Compact) 1.7 Commissioning 3. Automatic Restart After you have entered all necessary information and the operating system is configured, the PC automatically restarts and displays the user interface of the operating system. Note System startup can take longer than usual for the initial commissioning. When you switch on the PC now, the user interface of the Windows 2000 / Windows XP Professional operating system is automatically opened when the startup routine is completed.
Operating Instructions (Compact) 1.7 Commissioning 1.7.2 Setting up the language selection The Multilanguage User Interface (MUI) allows you to set up the Windows 2000 / Windows XP Professional menus and dialogs for additional languages. The default setting on your device is Windows 2000 / Windows XP MUI with English menus and dialog boxes and a US keyboard layout. You can change the language in the Control Panel.
Operating Instructions (Compact) 1.7 Commissioning 1.7.4 KeyTools (for key panel devices only) SIMATIC KeyTools is one selection of the applications for your Panel PC. These applications allow you to adapt key codes that are sent by the key panel of the control unit.
Operating Instructions (Compact) 1.7 Commissioning 1.7.5 Screen keyboard (for touch panel device only) You can operate the device by means of a virtual screen keyboard. You can use it to enter the characters directly on the touch screen or with an externally connected mouse. Calling up TouchInput Call up the "TouchInput" application on the desktop. The screen keyboard is displayed.
Operating Instructions (Compact) 1.8 Service and support 1.8 Service and support Additional support If you have any further questions relating to the products described in this documentation, contact your local representative at the SIEMENS office nearest you. Find your contact partner at: http://www.siemens.com/automation/partner A guide to the technical documentation for the various SIMATIC products and systems is available at: http://www.siemens.
Operating Instructions (Compact) 1.8 Service and support Service & support on the Internet In addition to our documentation, we offer our complete knowledge base on the Internet at. http://www.siemens.com/asis There you will find: • The newsletter which provides the latest information on your products • Relevant documentation for your application which you can access via the search function in our service & support database.
Operating Instructions (Compact) 1.