Operating instructions
Passive Components for Electrical Networks
4-18
SIMATIC NET Tw isted-Pair and Fiber-Optic Networks
C79000-G8976-C125-02
Table 4-9 Mechanical Data of the Twisted-Pair Cord
Standard code
LI02YSCY 2x2x0,15/0.98 PIMF GN
∅ Copper wire
0.5 mm
Outer dimensions approx. 3.7 x 5.8 mm
Thickness of the outer sheath approx. 0.5 mm
Bend radius:
single bend
multiple bends
≥ 20 mm over the narrow side
≥ 30 mm over the narrow side
Tensile strength:
≤ 48 N
Temperature range:
Operation
Installation/assembly
Transport/storage
-40
o
C...70
o
C
-20
o
C...50
o
C
-40
o
C...70
o
C
Net weight 33 kg/km
Free of halogens no
Resistance to fire Flame-retardant to DIN VDE 0472, Part 804 test type B
Versions Available
The following preassembled cables use TP cord:
S TP Cord RJ-45 / RJ-45 with 2 RJ-45 connectors
S TP XP Cord RJ-45 / RJ-45 with 2 RJ-45 connectors (crossover)
S TP cord 9/RJ-45 with one 9-pin sub-D and one RJ-45 connector
S TP cord 9 / RJ-45 with one 9-pin sub-D and one
RJ-45 connector (crossover)
S TP Cord 9 -45 / RJ-45 with one 9-pin sub-D male connector (45
o
cable outlet)
and one RJ-45 connector
S TP XP Cord 9-45/ RJ-45 with one 9-pin sub-D male connector (45
o
cable outlet)
and one RJ-45 connector (crossover)
S TP cord 9 / RJ-45 with one 9-pin sub-D and one (crossover)
S TP Cord RJ-45/15 with one 15-pin sub-D and one RJ-45 connector
S TP XP Cord RJ-45/15 with one 15-pin sub-D and one RJ-45 connector
(crossover)