Specifications

Comfort Panels Mobile Panels
High-end functionality for demanding HMI tasks Maximum mobility for operator control and monitoring
KTP400 Comfort
KP400 Comfort
TP700 Comfort
KP700 Comfort
TP900 Comfort
KP 900 Comfort
TP1200 Comfort
KP1200 Comfort
TP1500 Comfort
KP1500 Comfort
TP1900 Comfort TP2200 Comfort Mobile Panel 177 Mobile Panel 277 Mobile Panel
277 (F) IWLAN V2
Mobile Panel 277
4" Touch+Key
4" Key
7" Touch
7" Key
9" Touch
9" Key
12" Touch
12" Key
15" Touch
15" Key
19" Touch 22" Touch 6" Touch+Key 8" Touch+Key 8" Touch+Key 10" Touch
Widescreen TFT, 16 million colors, LED backlighting STN liquid crystal display
(LCD), 256 colors
TFT liquid crystal display
(LCD) 64K colors
TFT liquid crystal display
(LCD) 64K colors
TFT liquid crystal display
(LCD) 64K colors
Display
4.3“ 7.0“ 9.0“ 12.1“ 15.4“ 18.5“ 21.5 5.7“ 7.5“ 7.5“ 10.4“ Size (in inches)
480 x 272 800 x 480 800 x 480 1280 x 800 1280 x 800 1366 x 768 1920 x 1080 320 x 240 640 x 480 640 x 480 800 x 600 Resolution (W x H in pixels)
80,000 80,000 80,000 80,000 80,000 50,000 30,000 50,000 50,000 50,000 50,000 MTBF
10)
of backlighting (in h)
140 x 116
152 x 188
214 x 158
308 x 204
274 x 190
362 x 230
330 x 241
454 x 289
415 x 310
483 x 310
483 x 337 560 x 380 Diameter 245 Diameter 290 Diameter 290 Diameter 350 Front dimensions (in mm)
Touch screen and membrane
keypad or membrane keypad
Touch screen or
membrane keypad
Touch screen or
membrane keypad
Touch screen or
membrane keypad
Touch screen or
membrane keypad
Touch screen Touch screen Membrane keypad and
touch screen
Membrane keypad and
touch screen
Membrane keypad and
touch screen
Touch screen Operator controls
4 (w. LED) /
8 (w. LED) /
– / –
24 (w. LED) / •
– / –
26 (w. LED) / •
– / –
34 (w. LED) / •
– / –
36 (w. LED) / •
– / – – / – 14 / – 18 / – 18 / – – / –
Function keys (programmable) /
System keyboard
Usable memory
4 MB 12 MB 12 MB 12 MB 24 MB 24 MB 24 MB 2 MB 6 MB 6 MB 6 MB User memory
4 MB / 512 KB 12 MB / 2 MB 12 MB / 2 MB 12 MB / 2 MB 24 MB / 4 MB 24 MB / 4 MB 24 MB / 4 MB – / 32 KB 1024 KB / 64 KB 1024 KB / 64 KB 1024 KB / 64 KB Memory for options / recipes
7)
Message buffer
Interfaces
5)
/ • / • / 1
5)
/ • / • / 2
5)
/ • / • / 2
5)
/ • / • / 2
5)
/ • / • / 3
5)
/ • / • / 3
5)
/ • / • / 3 • / •
3)
/ •
3)
/ •
2)
• / • / • / • – / – / – / (• via IWLAN) • / • / • / • Serial / MPI / PROFIBUS DP/
PROFINET (Ethernet)
1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 – / – • / – • / – • / – USB host / USB device
– / – / 2 – / – / 2 – / – / 2 – / – / 2 / – / 2 – / – / 2 – / – / 2 – / • / – – / • / • – / • / • – / • / • Slot for CF / Multi Media / SD
Functionality (if configured
with WinCC V11)
2000 / 32 4000 / 32 4000 / 32 4000 / 32 6000 / 32 6000 / 32 6000 / 32 2000 / 32 4000 / 32 4000 / 32 4000 / 32 Signaling system (number
of messages/message classes)
500 500 500 500 750 750 750 500 500 500 500 Process pictures
1024 2048 2048 2048 4096 4096 4096 1024 2048 2048 2048 Variables
Vector graphics
• / f (t), f (x) • / f (t), f (x) • / f (t), f (x) • / f (t), f (x) • / f (t), f (x) • / f (t), f (x) • / f (t), f (x) • / • f(t) • / • f(t) • / • f(t) / • f(t) Bar graphs / curve diagrams
Faceplates
100 300 300 300 500 500 500 100 300 300 300 Recipes
10 / 50 50 / 100 50 / 100 50 / 100 200 / 200 200 / 200 200 / 200 – / – • / • • / • • / Archiving / Visual Basic Scripts
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL,
diagnostics viewer
STATUS/CONTROL STATUS/CONTROL STATUS/CONTROL STATUS/CONTROL Programming device functions
Connection to controller
• / • • / • • / • • / • • / • • / • • / • • / • • / • • / • • / • SIMATIC S7 / SIMATIC WinAC
– / – – / – – / – – / – – / – – / – – / –
3)6)
/ •
3)
6)
/ •
6)
/ • SIMATIC S5 / SIMATIC 505
– / – – / – – / – – / – – / – – / – – / – • / • • / • – / • (not Safety version) • / • SINUMERIK / SIMOTION
• / • • / • • / • • / • • / • • / • • / •
3)
/ •
3)
• / • – / – • / • Allen Bradley / Mitsubishi
• / • • / • • / • • / • • / • • / • • / •
3)
/ •
3)
• / • – / – • / • Modicon/Omron
Engineering software
WinCC Comfort V11 or
higher
WinCC Comfort V11 or
higher
WinCC Comfort V11 or
higher
WinCC Comfort V11 or
higher
WinCC Comfort V11 or higher WinCC Comfort V11 or higher WinCC Comfort V11 or
higher
WinCC Comfort V11 or
higher, WinCC flexible
Compact, Standard,
Advanced
WinCC Comfort V11 or
higher, WinCC flexible
Standard, Advanced
WinCC Comfort V11 or
higher, WinCC flexible
Standard, Advanced
WinCC Comfort V11 or
higher, WinCC flexible
Standard
Configuration
Options, application
• / • / • • / • / • • / • / • • / • / • • / • / • • / • / • • / • / •
2)
/ – / • • / • / • • / • / –
9)
• / – / – Sm@rtServer / Audit / Logon
• / • • / • • / • • / • • / • • / • • / • – / – • / • • / • • / • OPC server / Internet Explorer
6AV2124-1DC01-0AX0
6AV2124-2DC01-0AX0
6AV2124-0GC01-0AX0
6AV2124-1GC01-0AX0
6AV2124-0JC01-0AX0
6AV2124-1JC01-0AX0
6AV2124-0MC01-0AX0
6AV2124-1MC01-0AX0
6AV2124... 6AV2124... 6AV2124... 6AV6645-0AA01-0AX0
6AV6645-0BA01-0AX0
6AV6645-0CA01-0AX0 6AV6645-0DD01-0AX1 6AV6645-0BE02-0AX0 Order No.
*)
8)
Configuration with WinCC flexible 2008 or higher
9)
Only monitoring mode for Mobile Panel 277F IWLAN
10)
Reduction of brightness by 50%, can be extended by dimming and ProfiEnergy.
SO_Panels-TD_en-neu_mit-MLFBs.fm Seite 2 Montag, 5. Dezember 2011 11:17 11
DRAFT December 5, 2011
© Siemens AG 2011