Operating instructions
Table Of Contents
- SIMATIC IPC627C
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 Description
- 4 Application planning
- 5 Mounting
- 6 Connecting
- 7 Commissioning
- 8 Integration
- 9 Functions
- 10 Expansion and parameter assignment
- 11 Service and maintenance
- 11.1 Removing and installing hardware components
- 11.1.1 Repairs
- 11.1.2 Preventive maintenance
- 11.1.3 Replacing the Backup Battery
- 11.1.4 Removing/Installing the Power Supply
- 11.1.5 Installing / removing the bus board
- 11.1.6 Installing / removing the motherboard
- 11.1.7 Installing / removing the equipment fan
- 11.1.8 Installing / removing the power supply fan
- 11.1.9 Processor replacement
- 11.2 Reinstalling the software
- 11.2.1 General installation procedure
- 11.2.2 Restoring the Factory State of the Software Using the Restore DVD
- 11.2.3 Installing Windows
- 11.2.4 Setting up the language selection by means of the Multilanguage User Interface (MUI)
- 11.2.5 Recovery of Windows 7
- 11.2.6 Installing drivers and software
- 11.2.7 Installing the RAID Controller software
- 11.2.8 Installing the optional burner or DVD software
- 11.2.9 Update installation
- 11.2.10 Data backup / subsequent modification of partitions
- 11.2.11 CP 1616 onboard
- 11.3 Installing the RAID Controller software
- 11.4 BIOS update
- 11.5 BIOS Recovery
- 11.1 Removing and installing hardware components
- 12 Alarm, error, and system messages
- 13 Troubleshooting/FAQs
- 14 Technical data
- 15 Dimension drawings
- 16 Detailed descriptions
- A Appendix
- B ESD guidelines
- C List of abbreviations
- Glossary
- Index
SIMATIC IPC627C
Operating Instructions, 11/2010, A5E02669068-02
59
Functions
9
9.1 Introduction
Functions
The basic version of the device already has the following display, monitoring and control
functions:
● Temperature monitoring (over / under temperature)
● Watchdog (hardware or software reset of the computer)
● Monitoring of hard disks, CompactFlash cards and SSD drives with S.M.A.R.T.
functionality
● Operating hours meter (information on the cumulative run time)
● Monitoring of the battery level
● AMT (Active Management Technology)
SIMATIC PC DiagBase software
With the SIMATIC PC DiagBase software (included in product package), you can use the
display, monitoring and control functions. You use the "DiagBase Management Explorer"
application for general monitoring and "DiagBase Alarm Manager" for notification of
individual alarms.
the DMAPI programming interface for the DiagBase software is located on the DVCD
"Documentation&Drivers" in the folder "\Drivers\DiagBase\program
files\Siemens\DiagnosticManagement".
You will find further information on the functions of the SIMATIC PC DiagBase software in
the online help.
SIMATIC PC DiagMonitor software
The SIMATIC PC DiagMonitor software can be ordered on CD (does not ship with the
product). It contains the networkable monitoring software, the software for the stations to be
monitored and a library for creating custom applications.
AMT (Active Management Technology)
AMT is a technology from Intel for remote maintenance of computers. You turn an AMT PC
on and off remotely and start the BIOS setup remotely. Different operating systems can be
booted with ISO files.