Commissioning
7
7.1 Requirements for commissioning
CAUTION
Risk of damage to the device!
Make sufficient allowances for the device to acquire room temperature before you put it into
use. If condensation has developed on the device wait at least 12 hours before you switch it
on.
Note
The device features an off/off switch and an on/off button.
By default, the BIOS Setup entry "After Power Failure" is set to "Power On". This means that
the device is turned on using the on/off switch.
If the BIOS Setup entry is set to "Stay Off" or "Last state" and the on/off switch is set to "I"
(ON), the device can only be turned on by pressing the on/off button.
Connect the peripherals, such as the keyboard, mouse, monitor and the power supply,
before putting the device into operation.
The operating system you ordered for your device is already installed on the hard disk.
7.2 Basic commissioning - initial startup
The PC operating system is automatically set up the first time you switch on the device.
Procedure:
1. Set the ON / Off switch to I position (On). The PC performs a POST. During the self-test,
this message appears:
Press <F2> go to SETUP Utility
Press <F12> go to Bootmanager
2. Wait until this message is cleared, then follow the instructions on the screen.
3. Type in the Product Key as required. You find this key on the "Certificate of
Authentication", in the "Product Key" line.
NOTICE
The PC may not be switched off when you run setup.
Do not change the default BIOS settings, otherwise the operating system setup may
become corrupted.
4. Automatic restart