Operating instructions
Table Of Contents
- SIMATIC IPC627C
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 Description
- 4 Application planning
- 5 Mounting
- 6 Connecting
- 7 Commissioning
- 8 Integration
- 9 Functions
- 10 Expansion and parameter assignment
- 11 Service and maintenance
- 11.1 Removing and installing hardware components
- 11.1.1 Repairs
- 11.1.2 Preventive maintenance
- 11.1.3 Replacing the Backup Battery
- 11.1.4 Removing/Installing the Power Supply
- 11.1.5 Installing / removing the bus board
- 11.1.6 Installing / removing the motherboard
- 11.1.7 Installing / removing the equipment fan
- 11.1.8 Installing / removing the power supply fan
- 11.1.9 Processor replacement
- 11.2 Reinstalling the software
- 11.2.1 General installation procedure
- 11.2.2 Restoring the Factory State of the Software Using the Restore DVD
- 11.2.3 Installing Windows
- 11.2.4 Setting up the language selection by means of the Multilanguage User Interface (MUI)
- 11.2.5 Recovery of Windows 7
- 11.2.6 Installing drivers and software
- 11.2.7 Installing the RAID Controller software
- 11.2.8 Installing the optional burner or DVD software
- 11.2.9 Update installation
- 11.2.10 Data backup / subsequent modification of partitions
- 11.2.11 CP 1616 onboard
- 11.3 Installing the RAID Controller software
- 11.4 BIOS update
- 11.5 BIOS Recovery
- 11.1 Removing and installing hardware components
- 12 Alarm, error, and system messages
- 13 Troubleshooting/FAQs
- 14 Technical data
- 15 Dimension drawings
- 16 Detailed descriptions
- A Appendix
- B ESD guidelines
- C List of abbreviations
- Glossary
- Index

SIMATIC IPC627C
Operating Instructions, 11/2010, A5E02669068-02
33
Mounting
5
5.1 Installing the device
The device is particularly suitable for installation in consoles, switch cabinets and
switchboards.
WARNING
Function test while installing the device in machines or execute systems
Following the results of a risk analysis, additional protection equipment on the machine or
the system is necessary to avoid endangering persons. With this, especially the
programming, configuration and wiring of the inserted I/O modules have to be executed, in
accordance with the necessary risk analysis identified safety performance (SIL, PL or Cat.).
The intended use of the device has to be secured.
The correct use of the device has to be verified with a function test on the system. This test
can detect programming, configuration and wiring errors. The test results have to be
documented and if necessary inserted into the relevant inputs.
5.2 Installing the device with mounting brackets
Screw-mounting the brackets
Two angle brackets are included in the product package. You can attach these to the PC
enclosure using six M3 x 6 mm screws.
①
Mount the brackets onto the device using the included M3 screws with a max. insertion depth
of 5 mm (included in package).
Instructions for wall mounting
Mounting examples
Material Hole diameter Mounting
Concrete 8 mm diameter, 60 mm depth Dowel: 8 mm, 50 mm, screws 4 mm, 50 mm
Plasterboard
(min. 13 mm thick)
14 mm diameter Tilting dowel, diameter 4 mm
min. length 50 mm
Metal
(min. 2 mm thick)
5 mm diameter Metal screws, diameter 4 mm
min. length 15 mm
WARNING
Ensure that the wall is capable of bearing four times the total weight of the device (including
the brackets and expansion modules). The total weight is approx. 7 kg.