Operating instructions
Table Of Contents
- SIMATIC IPC627C
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 Description
- 4 Application planning
- 5 Mounting
- 6 Connecting
- 7 Commissioning
- 8 Integration
- 9 Functions
- 10 Expansion and parameter assignment
- 11 Service and maintenance
- 11.1 Removing and installing hardware components
- 11.1.1 Repairs
- 11.1.2 Preventive maintenance
- 11.1.3 Replacing the Backup Battery
- 11.1.4 Removing/Installing the Power Supply
- 11.1.5 Installing / removing the bus board
- 11.1.6 Installing / removing the motherboard
- 11.1.7 Installing / removing the equipment fan
- 11.1.8 Installing / removing the power supply fan
- 11.1.9 Processor replacement
- 11.2 Reinstalling the software
- 11.2.1 General installation procedure
- 11.2.2 Restoring the Factory State of the Software Using the Restore DVD
- 11.2.3 Installing Windows
- 11.2.4 Setting up the language selection by means of the Multilanguage User Interface (MUI)
- 11.2.5 Recovery of Windows 7
- 11.2.6 Installing drivers and software
- 11.2.7 Installing the RAID Controller software
- 11.2.8 Installing the optional burner or DVD software
- 11.2.9 Update installation
- 11.2.10 Data backup / subsequent modification of partitions
- 11.2.11 CP 1616 onboard
- 11.3 Installing the RAID Controller software
- 11.4 BIOS update
- 11.5 BIOS Recovery
- 11.1 Removing and installing hardware components
- 12 Alarm, error, and system messages
- 13 Troubleshooting/FAQs
- 14 Technical data
- 15 Dimension drawings
- 16 Detailed descriptions
- A Appendix
- B ESD guidelines
- C List of abbreviations
- Glossary
- Index

Detailed descriptions
16.4 BIOS-Setup
SIMATIC IPC627C
164 Operating Instructions, 11/2010, A5E02669068-02
Entry Meaning
FW Update Settings Sets the user rights and the conditions under which ME firmware
updates can be transferred.
Set PRTC PRTC (protected real time clock) is an internal ME clock, that is
required in the ME, for example for comparing times with TLS &
Kerberos, time stamps of events. Period of validity: 1.1.2004 –
4.1.2021.
Power Control Specifies the power states S0, S3, S4 of the computer in which
the ME is activated.
Previous Menu Return to the main menu.
AMT configuration
Figure 16-16 Intel(R) AMT Configuration
Entry Meaning
Manageability Feature Selection Enable and disable all AMT features.
SOL/IDER/KVM Enable and disable the features SOL, IDE
redirection, KVM.
User Consent User consent settings. Forces the following
additional security behavior: When a user
attempts to establish a KVM connection remotely,
a six-figure number is displayed on the AMT PC.
The remote user must enter this number on the
help desk PC before the KVM connection can be
opened.
Previous Menu Return to the main menu.