16.4 BIOS-Setup
SIMATIC IPC627C
Operating Instructions, 11/2010, A5E02669068-02
163
Figure 16-14 MEBx main menu
Entry Meaning
Intel(R) ME General Settings Opens the submenu with the general ME settings
(see "ME General Settings").
Intel(R) AMT Configuration Opens the submenu for the AMT settings (see
"ME General Settings").
Exit Exits the MEBx.
ME general settings
Figure 16-15 MEBx Intel(R) ME platform configuration
You cannot see all the switches in the menu at the same time. Use the arrow buttons to
display the hidden switches.
Entry Meaning
Intel(R) ME State Control Enable ME: Normal operation
Disable ME: Stops ME at a very early boot stage to search for
errors.
When searching for errors, ME can then be excluded as a
possible source of error.
No ME activities on a BUS.
Change ME Password Used to change the password
Password Policy Password policy that specifies the conditions under which the
password can be modified remotely.
Network Setup Network settings, for example DHCP, IP address, host name,
domain name.
Activate Network Access Activates the network interface. This menu entry only exists if the
network is not activated.
Unconfigure Network Access Deactivates the network interface and resets the network settings
to their default values.
Remote Setup And Configuration Displays the current provisioning settings.