Operating instructions
Table Of Contents
- SIMATIC IPC627C
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 Description
- 4 Application planning
- 5 Mounting
- 6 Connecting
- 7 Commissioning
- 8 Integration
- 9 Functions
- 10 Expansion and parameter assignment
- 11 Service and maintenance
- 11.1 Removing and installing hardware components
- 11.1.1 Repairs
- 11.1.2 Preventive maintenance
- 11.1.3 Replacing the Backup Battery
- 11.1.4 Removing/Installing the Power Supply
- 11.1.5 Installing / removing the bus board
- 11.1.6 Installing / removing the motherboard
- 11.1.7 Installing / removing the equipment fan
- 11.1.8 Installing / removing the power supply fan
- 11.1.9 Processor replacement
- 11.2 Reinstalling the software
- 11.2.1 General installation procedure
- 11.2.2 Restoring the Factory State of the Software Using the Restore DVD
- 11.2.3 Installing Windows
- 11.2.4 Setting up the language selection by means of the Multilanguage User Interface (MUI)
- 11.2.5 Recovery of Windows 7
- 11.2.6 Installing drivers and software
- 11.2.7 Installing the RAID Controller software
- 11.2.8 Installing the optional burner or DVD software
- 11.2.9 Update installation
- 11.2.10 Data backup / subsequent modification of partitions
- 11.2.11 CP 1616 onboard
- 11.3 Installing the RAID Controller software
- 11.4 BIOS update
- 11.5 BIOS Recovery
- 11.1 Removing and installing hardware components
- 12 Alarm, error, and system messages
- 13 Troubleshooting/FAQs
- 14 Technical data
- 15 Dimension drawings
- 16 Detailed descriptions
- A Appendix
- B ESD guidelines
- C List of abbreviations
- Glossary
- Index

SIMATIC IPC627C
Operating Instructions, 11/2010, A5E02669068-02
115
Technical data
14
14.1 General Specifications
General specifications
Order numbers 6ES7647-6C...
Dimensions Without DVD burner: 297x267x80 (WxHxD in mm)
With DVD burner: 297x267x100
Weight approx. 7 kg
Supply voltage (AC) Nominal 100 - 240 V AC (-15% / +10%) (autorange)
Supply voltage (DC) Nominal 24 V DC (-20% / + 20%), SELV
Input current AC Continuous current up to 2.3 A (on start-up, up to 50A for 1
ms)
Input current DC Continuous current to 8 A (to 14 A for 30 ms at startup)
Line voltage frequency 50 - 60 Hz (47 to 63 Hz)
Transient current interruption according
to Namur
max. 20 ms
max. power consumption AC / DC Effective power 190 W / 210 W
Apparent power 250 VA / -
Maximum power loss and heat
dissipation
AC: 190 W = 190 J/s = 0.18 BTU/s
DC: 210 W = 210 J/s = 0.2 BTU/s
Efficiency > 80%
max. current output +5 V / 16.5 A
*
(18.5 W peak)
+3.3 V / 8.5 A
*
*
total of 90 W permitted
+12 V / 6.5 A (8 A peak)
-12 V / 0.3 A
The total sum of all voltages is max. 150 W.
Noise emission < 55 dB(A) according to EN ISO 7779
Degree of protection IP 20
Safety
Protection class Protection class I to IEC 61140
Safety regulations AC: EN 60950-1; UL60950-1; CAN/CSA C22.2 No 60950-1-
03
DC: EN 61131-2; UL508; CSA C22.2 No 142
Electromagnetic compatibility (EMC)
Emitted interference EN 61000-6-3, EN 61000-3-2 class D
EN 61000-3-3; FCC class A
Noise immunity:
Mains borne disturbance variables on
supply lines
± 2 kV, (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge symm)
± 2 kV; (according to IEC 61000-4-5; Surge asymm)
Noise immunity on signal lines ± 1 kV;(according to IEC 61000-4-4; Burst; Length < 30 m)
± 2 kV; (according to IEC 61000-4-4; Burst; Length > 30 m)
± 2 kV; (according to IEC 61000-4-5; Surge; Length > 30 m)
Immunity to discharges of static
electricity
± 6 kV contact discharge (according to IEC 61000-4-2)
± 8 kV air discharge (according to IEC 61000-4-2)