Operating instructions
Table Of Contents
- SIMATIC IPC627C
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 Description
- 4 Application planning
- 5 Mounting
- 6 Connecting
- 7 Commissioning
- 8 Integration
- 9 Functions
- 10 Expansion and parameter assignment
- 11 Service and maintenance
- 11.1 Removing and installing hardware components
- 11.1.1 Repairs
- 11.1.2 Preventive maintenance
- 11.1.3 Replacing the Backup Battery
- 11.1.4 Removing/Installing the Power Supply
- 11.1.5 Installing / removing the bus board
- 11.1.6 Installing / removing the motherboard
- 11.1.7 Installing / removing the equipment fan
- 11.1.8 Installing / removing the power supply fan
- 11.1.9 Processor replacement
- 11.2 Reinstalling the software
- 11.2.1 General installation procedure
- 11.2.2 Restoring the Factory State of the Software Using the Restore DVD
- 11.2.3 Installing Windows
- 11.2.4 Setting up the language selection by means of the Multilanguage User Interface (MUI)
- 11.2.5 Recovery of Windows 7
- 11.2.6 Installing drivers and software
- 11.2.7 Installing the RAID Controller software
- 11.2.8 Installing the optional burner or DVD software
- 11.2.9 Update installation
- 11.2.10 Data backup / subsequent modification of partitions
- 11.2.11 CP 1616 onboard
- 11.3 Installing the RAID Controller software
- 11.4 BIOS update
- 11.5 BIOS Recovery
- 11.1 Removing and installing hardware components
- 12 Alarm, error, and system messages
- 13 Troubleshooting/FAQs
- 14 Technical data
- 15 Dimension drawings
- 16 Detailed descriptions
- A Appendix
- B ESD guidelines
- C List of abbreviations
- Glossary
- Index

Service and maintenance
11.5 BIOS Recovery
SIMATIC IPC627C
102 Operating Instructions, 11/2010, A5E02669068-02
11.5 BIOS Recovery
The "BIOS-Recovery" function is used to reinstall the device when a BIOS is unusable.
The recovery resets all the BIOS setup settings to the default values. After successful
recovery, you will need to make these settings again if you require any customer-specific
values.
Procedure
1. Switch off the device.
2. Remove the device cover and plug the jumper
① to "Recovery".
3. Close the device cover.
4. Place the Siemens BIOS Update USB stick into an USB slot of the device front.
5. Connect the power supply and switch on the device.
Recovery is executed automatically and cannot be interrupted or operated. The recovery
progress will be displayed on the screen.
6. Complete the recovery:
– Switch off the device.
– Remove the device cover, plug the jumper
① to "Park position" and close the device
cover.
– Remove the USB stick.
– Switch on the device.
– Call up the BIOS Setup by pressing the F2 key. If necessary, reset the Setup values.