Specifications
AS-Interface
ASIsafe
SIMATIC FS400 light curtains
6/35
Siemens IK PI · 2009
6
■
Function (continued)
3-sensor direction muting
Three-sensor direction muting is configured in a similar way to
2-sensor parallel muting. Material can only be transported
through the light curtain in one direction. To trigger the muting
function, muting sensor M1 must first be activated, followed
by muting sensors M2 and M3. If the paths for muting sensors
M2 and M3 are interrupted, sensor M1 does not need to be
activated.
Parallel muting with 4 sensors
4-sensor parallel muting can be used advantageously wherever
• the transported material is too small to be acquired simulta-
neously by 4 sensors arranged sequentially,
• the available space is too small even for the crossover light
beams of 2-sensor parallel muting.
The function of 4-sensor parallel muting corresponds to that of
2-sensor parallel muting with the additional characteristic of the
muting activation signal being obtained from two sensor pairs.
Muting is triggered when within a 2.5 s interval, M2 is activated
with M3 or M1 is activated with M4.
Transceiver
The transceiver comprises a transmitter and receiver in a single
unit. The infrared light of the transmit diode is reflected twice
through 90° so that it returns to the receive diode of the trans-
ceiver. This creates a twin-beam light barrier that is more cost ef-
fective than conventional light barriers with separate transmitters
and receivers. 3RG78 45 series transceivers have integrated
contactor control and startup/restart inhibit. 3RG78 44 and
3SF78 44 series transceivers have additional integrated muting
functions. These devices include five 5-pin M12 sockets on the
front panel, to which the muting sensors can be directly con-
nected.
Cascading of devices: Host/guest combinations
Cascading of devices refers to lengthening the optical axis and
therefore the protective zone height, whereby protection on the
horizontal and vertical levels can be realized at the same time
using a flexible connecting cable between the host and guest
device. The safety outputs and the processor tasks are located
in the host device so that the guest devices can be connected
regardless of the function package or outputs.
The standard cable that can be used to connect the host to the
guest is already installed on the guest device. The host comes
with the appropriate M12 socket on its underside. Host devices
can only be operated together with a guest device.
The guest devices are from the 3RG78 42 series, but they
are also suitable for the 3SF78 42, 3RG78 44, 3SF78 44 and
3RG78 45 series. The guest device resolution can be combined
with any other resolution (e.g. the host device can have a 14 mm
resolution while a 30 or 50 mm resolution is sufficient for the
guest device.
PC software
PC software can be used to visualize and record the function of
the light curtains.
SafetyLab is the diagnostic and parameterization software for
3RG78 44 / 3SF78 44 light curtains, light grids and transceivers.
SafetyLab can be used for all available light curtain and light
grid function packages as of firmware Version 3.10:
• Blanking function package
• Muting function package
• Sequence control function package
The firmware version of the receiver is indicated on the
7-segment display during start-up.
Mounting sets
To facilitate installation, alignment, commissioning and trouble-
shooting, a practical accessories package containing mounting
columns, reflecting mirror columns, reflecting mirrors, mounting
supports and laser alignment tools is available.
Start
M2
M3
E
S
M1
E
S
Danger zone
Start
M1
M3
E
S
M4
M2
Danger zone