Specifications

AS-Interface
ASIsafe
3SF2 AS-Interface cable-operated switches
6/30
Siemens IK PI · 2009
6
Overview
AS-Interface cable-operated switches can now be directly
connected via the standard AS-Interface with safety-oriented
communication.
The safety functions no longer have to be conventionally wired
up.
Application
SIRIUS cable-operated switches are used for monitoring or for
EMERGENCY STOP devices on particularly endangered system
sections.
As the effective range of a cable-operated switch is only limited
by the length of the pull-rope, large systems can also be pro-
tected.
Standards
The switches with positive latching are suitable for operation
in EMERGENCY STOP devices in according to EN ISO 13850.
They are usable up to Category 4 according to EN 954-1.
Selection and ordering data
Version Basic switches Contacts Order No.
Cable-operated switches with AS-i F adapter
Metal enclosure with dust protection,
IP65,
latching according to EN ISO 13850,
with button reset
• For rope lengths up to 10 m,
with alignment window
3SE7 120-1BF00 2 NC
q
3SF2 120-1BF00-0BA1
• For rope lengths up to 25 m,
with alignment window
3SE7 150-1BF00 2 NC
q
3SF2 150-1BF00-0BA1
• For rope lengths up to 50 m 3SE7 140-1BF00 2 NC
q
3SF2 140-1BF00-0BA1