SIMATIC Box PC 620 Getting Started Edition 04/2003 First Steps in Commissioning Valid for devices with the order number 6ES7647-5...
Safety guidelines This Getting Started contains notices intended to ensure personal safety, as well as to protect the products and connected equipment against damage. These notices are highlighted by the symbols shown below and graded according to severity by the following texts: ! ! ! Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.
This Getting Started offers you step by step instructions on how to install and start the Box PC 620. Unpacking the Box PC 620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installing the Box PC 620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Hardware Components of the Box PC 620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Connection to the Power Supply Unit . . . . . . . . . . . . . . . . . . . . .
Recording the Serial Number and the Ethernet address 6. Enter the serial number and the Ethernet address of your PC in the table below. You can find the serial number on the type label attached to the rear of the device. The Ethernet address can be found in the BIOS setup settings in the main menu under the ’Hardware Options’ function. The device can precisely be identified with the help of these numbers in case of repairs or theft.
Depending on the configuration of the device, two mounting brackets are included in the scope of delivery. You can attach these to the housing with 6 screws (M3x6). M4 thread, max. depth of engagement 5 mm M3 thread, max. depth of engagement 5 mm Equipotential grounding connection Instructions for wall and ceiling mounting To install the Box PC 620 at a concrete wall or ceiling proceed as follows: 1. Fix the mounting brackets at the housing of the PC. 2.
Dimension Drawings for Fitting in Control Panel with Installation Angle (Device without CD ROM Drive) 297.2 266 5 301 286 80.1 232 26 11.
Dimension Drawings for Fitting in Control Panel (Device with CD ROM Drive) 99.1 286 301 297.
Dimension Drawings for Fitting in Control Panel without Installation Angle 297.2 267 80.1 11.
Permissible Fitting Positions of the PC to UL1950/EN60950/CSA22.2 No. 950 An inclined position of + 20_ is allowed in each of the permissible fitting positions.
Additional Permissible Fitting Positions of the PC to UL508/CSA 22.2 No. 142 An inclined position of $15_ is allowed in each of the permissible fitting positions. An external fire protection housing is not necessary.
+ Hardware Components of the Box PC 620 Port Side View 1 2 34 12 11 13 1 5 10 9 8 6 7 Mouse PS/2 socket for connecting a PS/2 mouse. 2 COM1 V.24 /MODEM /AG The COM 1 (TTY) port is used to connect, for example, S5 automation units (AG). The supplied adapter can be used to convert the port into a 25-pole standard V.24 port for connecting serial port devices such as modem, mouse or printer. Refer to Section 3.4 of the electronic manual.
10 USB 2 Universal Serial Bus connectors. You can use the USB port to connect external devices, for example, CD drives, printers, modems as well as mouse and keyboard. Older operating systems do not support this port. 11 VGA You can connect an external VGA monitor to this connector. 12 LPT1 The parallel port connection for devices with parallel port (for example, printer) 13 Keyboard Connection for a PS/2 keyboard.
4 Front Ports The front ports are located behind the cover below the floppy disk drive. They are used for connection of the following front elements: • I/O port for the connection of front components • LVDS display port 5 Reset Button The reset button can be actuated with a pointed object (e.g. an opened up paper clip). If you actuate, the button, a hardware reset is triggered. The PC restarts. Data loss is possible with a hardware reset.
3 Certificate of Authenticity with Product Key You need the Microsoft Windows “Product Key” on the “Certificate of Authenticity” if you reinstall software. + Connection to the Power Supply Unit ! Warning The Box PC 620 with AC power supply is equipped with a safety-tested mains cable and may only be connected to a grounded grounding outlet. Make sure that the socket on the device or the grounding outlet of the building installation is easily accessible and as near as possible to the device.
+ Powering Up the Box PC 620 The operating system supplied with the Box PC 620 is preinstalled on the hard disk. When powering up the device you have to distinguish between the following: • Initial start to set up the PCs software and a • Complete restart after initial start. Caution Your PC must be switched off when inserting/removing peripheral connectors (keyboard, mouse, printer, etc.). Otherwise, your PC could be damaged.
+ Reinstallation of the Software In case of software errors reinstall your software using the Recovery CD, the Documentation and Drivers CD and the Restore CD. Recovery CD: contains the tools for installing the hard disk and the operating systems. Documentation and Drivers CD: contains the documentation and the hardware drivers. Restore CD: contains an Image file with the original delivery software.
No response from ports COM1,COM2, LPT1 or PROFIBUS/MPI • Ports are set to ”Disabled”in the BIOS Setup program. • Set the ports COM1,COM2, LPT1 or PROFIBUS/MPI to ”Enabled” in the submenu ”Hardware Options” in the BIOS Setup program.
A&D Technical Support Worldwide, available 24 hours a day: Nuernberg Johnson City Beijing Technical Support Worldwide (Nuernberg) Technical Support 24 hours a day, 365 days a year Phone: +49 (0) 180 5050-222 Fax: +49 (0) 180 5050-223 E-Mail: adsupport@ siemens.com GMT: +1:00 Europe / Africa (Nuernberg) United States (Johnson City) Asia / Australia (Beijing) Authorization Technical Support and Authorization Technical Support and Authorization Local time: Mon.-Fri.
+ Certificates, Directives and Declarations Notes on the CE Symbol The following applies to the SIMATIC product described in this Getting Started: EMC Directive Devices with a power supply performance of 85W are in accordance with the EU Directive 89/336/EEC “Electromagnetic Compatibility.
Observing the Installation Guidelines The installation guidelines and safety instructions specified in this documentation or the electronic manual must be observed during startup and operation. Connecting Peripherals The requirements regarding noise immunity (EN50082-2:1995) are met when you connect a peripheral suitable for an industrial environment. Peripheral devices are only be connected via shielded cables.
EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Siemens AG Organization Group Automation and Drives 22 Systems Engineering Division Postfach 2355, DĆ90766 Fuerth Siemens Aktiengesellschaft E Siemens AG 2002Ć2003 Subject to technical change. A5E00131477Ć03 Printed in the Fed. Rep.