Technical data

Setting Up and Operating the SIMATIC Box PC 620
4-16
SIMATIC Box PC 620 Manual
C79000-G7076-C639-02
SIMATIC Box PC 620 to PG Connection (V.24, TTY)
If you want to connect your SIMATIC Box PC 620 to another programming device,
you can plug the appropriate connecting cable into the V.24 or TTY interface port
Tabelle 4-2 Connection of the SIMATIC Box PC 620 to other PUs
Interface Link Connecting Cable
Order No.:
Adapter
COM 1 as a
V.24 port
PG 7xx with PG 7xx 6ES5 733-5BD20
2)
COM 1 as a
TTY port
PG 7xx with PG 6xx Series connection of
6ES5733-2xxx0
2)
and
6ES5731-6AG00
1)
6ES5 731-6AG00
Note
1. When connecting the programming devices in series, make sure you connect the cable
the right way around (see Figure 4-9).
2. The connecting cable is available for order only as a spare part. The connecting cable is
described in Chapter 8.
Adapter Connecting cable
Active Passive
6ES5 731–6AG00 6ES5 733–2xxx0
PG 7XX
PG 6XX
Figure 4-9 Direction of Connection: Adapter – Connecting Cable
Note
For the PC/PU connection, you must switch the TTY ports (COM 1) in one of the
programmable logic controllers to passive by changing the jumper setting. When
the SIMATIC Box PC 620 leaves the factory, this interface is always set to active!