User manual
Configuration with the CCIC1410 Homepage 
61 
Siemens Building Technologies   
Fire Safety & Security Products    05.2009
z  Security: WEP (Wired equivalent Privacy): 
It allows communication only with other devices with identical WEP settings. 
–  Authentication mode: 
Î Open 
"Open" is the default setting and means that the key will be 
communicated across the network. 
Î Shared: 
"Shared" allows communication only with other devices with identical 
WEP settings. 
–  Key length: 
The administrator can select the key length among 64 or 128 bits. 64 bits is 
the default setting. 
–  Key format: 
Hexadecimal or ASCII. HEX is the default setting. HEX digits consist of the 
numbers 0 – 9 and the letters A – F. ASCII is a code for representing 
English letters as numbers from 0 – 127 except “, <, > and space 
characters that are reserved. 
–  Default Key - Network Key: 
Enter a key in either hexadecimal or ASCII format. You can select different 
key lengths. Acceptable input lengths are as follows: 64 bits key length: 
10 Hex digits or 5 characters. 128 bites key length: 26 Hex digits or 13 
characters. 