Specifications

Connecting
5.1 Ports
SCALANCE X-400 BA
96 Operating Instructions, 03/2009, C79000-G8976-C186-07
Conn. 1 IN1 Digital input 1
IN2 Digital input 2
M4 Ground
IN3 Digital input 3
IN4 Digital input 4
Digital inputs 5 to 8 on male connector X2
Digital inputs 5 through 8 are connected using a 5-pin connector at the rear terminal block on
the DI module.
,1 ,1 0 ,1 ,1
Figure 5-4 Pins of connector X2 (inputs 5-8)
IN5 Digital input 5
IN6 Digital input 6
M5 Ground
IN7 Digital input 7
Conn. 2
IN8 Digital input 8
5.1.4 Connectors for the twisted pair cables
The FastConnect cabling system
With the IE FC RJ-45 Plug and the FastConnect cables (FC), you can achieve a segment
length up to 100 m without patching. In this case, the IE FC standard cable 2x2 is connected
directly to the SCALANCE X414-3E and other components on the network.