Specifications

Description
3.4 Description of the product
SCALANCE X-400 BA
64 Operating Instructions, 03/2009, C79000-G8976-C186-07
the diagnostics mechanisms of the device (LEDs, WEB-based management, SNMP, and
CLI).
Startup behavior
C-PLUG IE Switch X-400 startup
1 not found with internal configuration (if it exists) or with
factory defaults.
2 empty with internal configuration, immediately copies
this automatically to the C-PLUG
3 written with own configuration data with C-PLUG configuration
4 written with other configuration data with third-party C-PLUG configuration
5 written with configuration data of a
different device type
with internal configuration, red LED on power
module and log entry
6 defective with internal configuration, red LED on power
module and log entry
In cases 1 and 2, the configuration data on the CPU module and the C-PLUG is identical. In
cases 3 and 5 the configuration data is different and can be synchronized manually. In case
6, you can attempt to reformat the C-PLUG with the clean function. If problems persist,
replace the C-PLUG.
NOTICE
When using a SCALANCE X414-3E, in case 4 (replacing the switch), the DIL switch
settings of the C-PLUG and not the physical switch settings are adopted. A deviation is
signaled by the diagnostic options.
For more detailed information, refer to the configuration manual "SCALANCE X-300
SCALANCE X-400 Industrial Ethernet Switches".
3.4.7 SCALANCE X-400 covers and dummy covers
3.4.7.1 SCALANCE X414-3E covers/dummy covers
Slots of the covers
Note
The protective caps for the media module terminal strips and the covers must be fitted in all
slots that do not contain media modules.
For slots for twisted pair (9 through 11), the covers are recommended to protect the RJ-45
jacks.