Specifications
Description
3.4 Description of the product
SCALANCE X-400 BA
36 Operating Instructions, 03/2009, C79000-G8976-C186-07
● Slot 4
CPU module contains
– the Ethernet port, only for commissioning and configuration of the X414-3E.
– the serial RS-232 port for firmware update or management over the Command Line
Interface (CLI).
– the C-PLUG for storage of parameter assignments.
– the DIL switch for the redundancy manager function and to specify the ring ports.
– the SELECT/SET button for device display and configuration.
– the LED display for redundancy manager and standby mode as well as display modes
Dmode A through Dmode D.
● Slot 5
Contains two RJ-45 jacks allowing attachment of electrical (twisted pair) connections (10,
100, 1000 Mbps). As an option, slot 5 allows the use of an optical gigabit module with two
ports (1000Base-SX or 1000Base-LX).
● Slots 6 and 7
Optional use of two optical Fast Ethernet modules (100 Mbps) each with two ports
(100Base-FX).
● Slot 8
No function in system.
● Slot 9 through 11
Each contains four RJ-45 jacks allowing attachment of 12 electrical (twisted pair)
connections in total (10, 100 Mbps). These cannot be used by media modules.
3.4.2.1 SCALANCE X414-3E power module
The power module is located in slot 2.
The power module can be supplied with power redundantly over two inputs. The two power
inputs are isolated from each other, there is no power distribution. If redundant power feed-in
is used, the switch is supplied solely by the section of the power module with the higher
output voltage.
The front 4-pin connector is used for the power supply. The input voltage is 24 V DC (20.4 –
28.8 V). The signaling contact supplies the fault status at the rear 4-pin connector. If there is
a fault, the contact opens.