Specifications

Description
3.3 System description of SCALANCE X-400
SCALANCE X-400 BA
Operating Instructions, 03/2009, C79000-G8976-C186-07
29
Half duplex
Full duplex
Transmission medium
Data is transmitted over an eight-wire twisted pair cable.
NOTICE
For data transmission at 1 Gbps, at least a Cat 5e twisted-pair cable with 4 x 2 wires is
necessary. With a four-wire cable (2 x 2 wires), a maximum data transmission rate of 100
Mbps is possible.
Transmission range
The maximum transmission range (segment length) is 100 m.
Connectors
The connectors used are 8-pin RJ-45 jacks.
3.3.2.3 100Base-FX
Transmission rate
The transmission rate of the optical Fast Ethernet ports is 100 Mbps.
Transmission mode
Transmission with 100Base-FX is defined in the IEEE 802.3u standard and is specified as
100 Mbps transmission rate and full duplex.
Transmission medium
Data transmission is over multimode or single mode fiber-optic cable (FOC).
Two FOC types can be used:
Multimode FOC
The core diameter is 50 µm; the light source is an LED. Many modes are used for signal
transmission. The propagation times of the light pulses (dispersion) restrict the maximum
range considerably.
Single mode FOC
The core diameter is 9 or 10 µm; the light source is a laser diode. To transmit a signal,
only one mode is used greatly reducing dispersion. As a result, the maximum range of
single mode FOC is greater than that of multimode FOC.
Regardless of the type used, the outer diameter of the FOC is 125 µm.