Specifications
Description
3.2 Network topologies
SCALANCE X-400 BA
Operating Instructions, 03/2009, C79000-G8976-C186-07
13
Table 3- 2 Electrical ports (on the slots)
Transmission rate SCALANCE X414-3E SCALANCE X408-2
Gigabit 5 5 and 6
Fast Ethernet 5 and 9 to 11
with extender: 12 and 13
5, 6 and 8
With the fault mask, it is possible to monitor the port states using the signaling contact. In
addition to interconnecting the switches, it is also possible to connect one or more end
devices to every IE Switch X-400.
Configuration example
Sample configuration with SCALANCE X414-3E, SIMATIC S7-300/400 and operator panel
as end devices.
S7-300S7-400 ET 200SS7-400 S7-300 S7-300
ET 200SET 200S ET 200S ET 200S
SCALANCE
X414-3E
S7-300S7-400
Fiber Optic
SCALANCE
X414-3E
SCALANCE
X414-3E
SCALANCE
X414-3E
Figure 3-1 Linear structure (optical)
3.2.2 Star/tree structure
Functional description
Star/tree structures can be created with IE Switches X-400. The cascading depth and total
span of a network are limited only by the signal propagation times of the communication
connections.
Properties of a star structure
Each IE Switch X-400 communicates over a TP or FO cable with a central switch with which
all other switches are also connected within a star structure. Communication is possible over
the optical or the electrical ports.